| SPECIFICATION AO300-09TNF |
| Page1 |
| TABLE OF CONTENTS |
| 1. GENERAL REQUIREMENTS |
| 2. INPUT REQUIREMENTS |
| 3. OUTPUT REQUIREMENTS |
| 3.1 OUTPUT VOLTAGE AND CURRENT |
| 3.2 REMOTE ON/OFF CONTROL |
| 3.3 OUTPUT VOLTAGE HOLD-UP TIME |
| 3.4 OPERATION AT NO LOAD |
| 3.5 PROTECTION |
| 3.6 OUTPUT RISETIME |
| 3.7 OUTPUT OVERSHOOT |
| 3.8 EFFICIENCY |
| 3.9 POWER GOOD SIGNAL |
| 3.10 POWER FAIL SIGNAL |
| 3.11 POWER ON TIME |
| PAGE |
| 3 |
| 3 |
| 3 |
| 3 4 4 4 4 5 5 5 5 6 6 |
| 6 |
| 6 7 7 |
| 7 |
| 7 7 7 7 7 |
| 8 |
| 8 8 8 9 |
| 4. PHYSICAL ENVIRONMENT |
| 4.1 OPERATING CONDITIONS |
| 4.2 STORAGE AND SHIPPING CONDITIONS |
| 4.3 SHOCK AND CONDITIONS |
| 5. REGULATORY COMPLIANCE |
| 5.1 SAFETY REQUIREMENTS |
| 5.2 DIELECTRIC STREENGTH |
| 5.3 INSULATION RESISTANCE |
| 5.4 GROUND LEAKAGE CURRENT |
| 5.5 EMISSION REQUIREMENTS |
| 6. OTHER REQUIREMENTS |
| 6.1 COOLING |
| 6.2 INPUT CONNECTIONS AND CONTROLS |
| 6.3 RELIABILITY |
| 7 REVISION HISTORY |
| Page2 |
| 1.0 |
| GENERAL REQUIREMENTS This specification describes a 300 watts power supply. With+ 5V stand-by , remote ON/OFF control for ATX system . |
| 2.0 |
| INPUT REQUIREMENTS |
| The power supply shall operate in ±10% of 230 Vrms. The power supply shall operate from an AC mains frequency of 47 through 53 Hz. The Ac mains single-cycle peak inrush current shall be limited to 60 amps cold, 90 amps warm measured at 264 Vrms, 50 Hz and coinciding with the AC main voltage peak. The AC mains steady-state RMS input current shall be: 3.5 amps maximum / 230 Vrms, 50 Hz. |
| 3.0 |
| OUTPUT REQUIREMENTS |
| 3.1 OUTPUT VOLTAGE AND CURRENT |
| MINIMUM NORMAL MAXIMUM LOADLOADLOAD |
| +3.3V +5V +12V1DC +12V2DC -12V +5Vsb |
| 0.5A 1.0A 1.0A 1.0A 0.0A 0.0A |
| 10.0A 10.0A 4.0A 7.0A 0.4A 1.0A |
| 20A 20A 8.0A 14.0A 0.8A 2.0A |
| RIPPLE & NOISE |
| 60mV P-P 60mV P-P 150mV P-P 150mV P-P 150mV P-P 70mV P-P |
| LOAD REG. ±5% ±5% ±5% ±5% ±10% ±5% |
| LINE REG. |
| ±1% ±1% ±1% ±1% ±2% ±1% |
| (1). +3.3V &+5V total output not exceed 120W. When +3.3V is load to 20A,the +5V maximum load is 10.8A. When +3.3V is load to 6.0A,the +5V maximum load is 20A. (2). +3.3V &+5V & +12V1DC & +12V2DC total output not exceed 280W.. (3) All outputs shall be safety-isolated from the AC mains and share a common return. This common return must be connected to supply chassis. (4) Voltages and ripple are measured at the load side of mating connectors with a 0.1 uF monolithic ceramic capacitor paralleled by a 10 uF electrolytic capacitor across the measuring terminals. |
| Page3 |
| LOAD REGULATION CHARACTERISTICS OUTPUT LOADLOAD NO. CONDITION+3.3V+5V+12V1DC +12V2DC 1COND.10A0A0A0A 2COND.20.5A1.0AA1.0A1.0A 3COND.32.5A2.0A1.0A1.0A 4COND.417.0A8.0A2.0A3.0A 5COND.56.0A18.0A3.0A5.0A 6COND.66.5A6.8A5.5A10.0A 7COND.70.5A7.0A8.0A14.0A 8COND.80.5A5.0A8.0A14.0A 9COND.91.0A3.0A3.0A5.0A |
| -12V 0A 0.1A 0.3A 0.1A 0.3A 0.3A 0.1A 0.3A 0.1A |
| +5Vsb 2.0A 1.0A 1.5A 2.0A 0.5A 1.0A 0.0A 0.0A 2.0A |
| 3.2 |
| REMOTE ON/OFF CONTROL |
| The power supply shall accept a logic open collector level which will disable |
| / enable all the output voltage (exclude + 5V standby ). As logic level is low, outputs voltage were enable. As logic level is high, outputs voltage were disable. Note: 1. Logic high level :3.50-5.25V while sourcing 0.4mA maximum. 2. Logic low level : 0-0.5V while sinking 1.5mA maximum. 3. Rise Time : 2ms maximum (10%-90%). |
| 3.3 |
| OUTPUT VOLTAGE HOLD-UP TIME |
| 10.0 mS minimum : at 230V / 50 Hz. |
| 3.4 OPERATION AT NO LOAD |
| The power supply shall be capable of being operated with no load on any or all outputs without damage. For no load on +3.3V&+5V, the output shall not exceed +4.5 & +6.5Vdc and the power supply may shutdown and require by remote-control or remove AC power restart. |
| 3.5 |
| PROTECTION |
| OVER-VOLTAGE |
| PROTECTION |
| 3 .5.1 |
| In the event of an over-voltage condition on +3.3 & +5Vdc &+12V the power supply shall shutdown and require remote control or remove the AC mains input to reset the system. |
| +5V: 6.5V(maximum) +3.3V: 4.6V(maximum) +12V1DC : 15.5V(maximum) +12V2DC : 15.5V(maximum) |
| Page4 |
| 3 .5.2 |
| O V E R -CURRENT |
| PROTECTION |
| There shall be protection from an output over-current event. The supply may shutdown form such an event and require power-on restart. Testing consists of application of the listed over-current value with maximum load on all other outputs. Over-current test values: (maximum load) +3.3V :65A maximum +5V:50A maximum +12V1DC :21A maximum +12V2DC :27A maximum |
| 3 .5.3 |
| S H O R T -C U R R E N T P R O T E C T I O N |
| A short circuit at any output shall cause no damage to the power supply nor blow the primary fuse. The supply may shut down in the event of a short circuit and require power-on restart. A short circuit consists of application of a test resistance of less than 0.05 ohms at each output with maximum load on all outputs. |
| 3.6 OUTPUT RISETIME |
| The cold-start enable output voltage risetime of all outputs shall be measured with maximum load on all outputs. risetime : +3.3V20mS (maximum) (10-95%)+5V20mS (maximum) +12 V1DC20mS (maximum) +12 V2DC20mS (maximum) -12 V20mS (maximum) |
| +5Vsb |
| 20mS (maximum) |
| 3.7 OUTPUT OVERSHOOT |
| No output voltage shall overshoot or generate spikes at turn-on or turn-off, during momentary power loss, output short, or realistic input voltage or output load changes, Overshoot is defined as any output that exceeds the voltage tolerance plus or minus an additional 5%. |
| 3.8 |
| EFFICIENCY |
| Overall efficiency must be 65% minimum measured at normal AC mains voltage and frequency with maximum loads on all outputs. |
| 3.9 POWER GOOD SIGNAL |
| 230V (FULL LOAD) : 100-500mS |
| Page5 |
| 3.10 |
| POWER FAIL SIGNAL |
| 230V (FULL LOAD) : 1mS minimum. |
| 3.11 |
| POWER ON TIME 230V(FULL LOAD) : 500mS |
| maximum. |
| PS-ON |
| 95% |
| 10% |
| ~ ~ |
| ~ |
| T5 |
| DC OUTPUT |
| ~ |
| P.G. SIGNAL |
| T2 |
| T3 |
| T4 |
| Figure 1 |
| T2 : RISETIME < 20mS T3 : POWER GOOD DELAY TIME 100mS-500mS T4 : POWER FAIL DELAY TIME >1mS T5 : POWER GOOD RISETIME ≦10mS |
| 4.0 |
| PHYSICAL ENVIRONMENT |
| 4.1 OPERATING CONDITIONS |
| The power supply shall be capable of continuous operation and meet all electrical specification without need for adjustment when subjected to the following environmental conditions: |
| 4.1 .1 AMBIENT TEMPERATURE : 0 TO 50℃ |
| The maximum continuous power rating of supply is 300W at 25℃ .De-rate |
| 2W/℃ from 50℃ to 25℃. |
| 4.1.2 |
| RELATIVE HUMIDITY : 90% |
| Page6 |
| 4.2 STORAGE AND SHIPPING CONDITIONS |
| No degradation of the power supply shall occur during shipping or storage at the specified conditions. |
| 4 .2.1 |
| 4.2 .2 |
| AMBIEN T TE MPE RATU RE : -20 TO +65℃ |
| RE LATIV E HU MIDI TY : 95% |
| 4.3 |
| SHOCK AND VIBRATION |
| The power supply will withstand the following imposed conditions without experiencing non-recoverable failure or deviation form specified output characteristics. Storage -40G,11mSec. half-sine wave pulse in both directions on three mutually perpendicular axes. Operating -10G, 11mSec. half-sine wave pulse in both directions on three |
| mutually perpendicular axes. Vibration Operation-Sine wave excited, 0.25G maximum acceleration. 10- 250 Hz, swept at one octave/min. Fifteen minute dwell at all resonant points, where resonance is defined as those exciting frequencies at which the device under test experiences excursions two times large than non-resonant excursions. |
| 5.0REGULATORY COMPLIANCE 5.1 SAFETY REQUIREMENTS |
| -IEC 60950 -TUV EN60950 -UL 60950 - NEMKO + CB REPORT |
| 5.2 DIELECTRIC STRENGTH |
| Primary to Frame Ground : 1800 Vac for 1 sec. Primary to Secondary : 1800 Vac for 1 sec. |
| 5.3 INSULATION RESISTANCE |
| Primary to Secondary : 20 Meg. ohms Minimum. Primary to FRAME GROUND : 20 Meg. ohms Minimum. |
| 5.4 GROUND LEAKAGE CURRENT |
| The power supply ground leakage current shall be less than 3.5mA. |
| 5.5 EMISSION REQUIREMENTS |
| When testing the power supply must operate within the listed requirements. |
| Page7 |
| 6.0 |
| 6.1 |
| OTHER REQUIREMENTS |
| COOLING |
| With the fan voltage set to around 12 volts, the fan will deliver greater than 38.6 CFM with the power supply in open air. |
| 6.2 INPUT CONNECTIONS |
| Refer to Mechanical Specifications for placement. The AC mains input are through a three-circuit IEC type connector mounted on the rear of the power supply chassis. |
| 6.3 RELIABILITY |
| The power supply reliability, when calculated by MIL-HDBK-217; latest revision, are exceed 100,000 hours with all output at maximum load and an ambient temperature of 25℃. |
| Page8 |
| 7.0 Revision History: |
| Rev |
| Description |
| Date |
| Page9 |